Zaon Forums
Welcome, Guest
Please Login or Register.    Lost Password?
Brief Power-up, Power-down (1 viewing) (1) Guests
Go to bottom Post Reply Favoured: 0
TOPIC: Brief Power-up, Power-down
#98
faq (User)
Senior Boarder
Posts: 40
graphgraph
User Offline Click here to see the profile of this user
Brief Power-up, Power-down 4 Years, 5 Months ago Karma: 1  
Unit powers on, the display briefly illuminates, then unit immediately shuts off.

Check all connections for proper installation. Unit will shut off automatically if a short in the system is detected or the power has been applied to the system for less than 4 seconds. There is a 4 second delay between the times the power is first applied, to when XRX will be allowed to start. This period of time is used to smooth any interference coming in on the power cord. If the system detects too much noise it will shut down. If unit never starts up, unit needs to be repaired.
 
Report to moderator   Logged Logged  